Ø d1
20 mm
S
2 mm
Specific load I
287 bar
Please choose a variant
Article
PR 04-1 V4
PR 06-0.5 V4
PR 06-1 V4
PR 06-1.5 V4
PR 06-2 V4
PR 08-1 V4
PR 08-1.5 V4
PR 08-2 V4
PR 10-0.5 V4
PR 10-1 V4
PR 10-1.5 V4
PR 10-2 V4
PR 12-1 V4
PR 12-1.5 V4
PR 12-2 V4
PR 12-3 V4
PR 14-1.5 V4
PR 14-2 V4
PR 14-2.5 V4
PR 15-1 V4
PR 15-1.5 V4
PR 15-2 V4
PR 16-1.5 V4
PR 16-2 V4
PR 16-2.5 V4
PR 16-3 V4
PR 18-1 V4
PR 18-1.5 V4
PR 18-2 V4
PR 18-2.5 V4
PR 20-2 V4
PR 20-2.5 V4
PR 20-3 V4
PR 20-3.5 V4
PR 22-1.5 V4
PR 22-2 V4
PR 22-2.5 V4
PR 22-3 V4
PR 22-4 V4
PR 25-1.5 V4
PR 25-2 V4
PR 25-2.5 V4
PR 25-3 V4
PR 25-4 V4
PR 28-1.5 V4
PR 28-2 V4
PR 28-2.5 V4
PR 30-2 V4
PR 30-2.5 V4
PR 30-3 V4
PR 30-4 V4
PR 30-5 V4
PR 35-1.5 V 4
PR 35-2 V4
PR 35-2.5 V4
PR 35-3 V4
PR 35-4 V4
PR 35-5 V 4
PR 38-3 V4
PR 38-4 V4
PR 38-5 V4
PR 38-6 V4
PR 42-2 V4
PR 42-3 V4
Product details for
PR 20-2 V4
Ø d1
20 mm
S
2 mm
Specific load I
287 bar
Specific load III
213 bar
Ø d2
16 mm
AD tolerance +/-
0.08 mm
ID tolerance +/-
0.08 mm
All characteristics
Characteristics
Konstrukce
- přesné ocelové trubky, bezešvé (tažené za studena), metrické
Konstrukční doplněk
- CFA = bright annealed (annealed, metallically bright)
Materiál
- stainless steel X6CrNiMoTi17-12-2 (1.4571 / AISI 316Ti)
Norma
- DIN EN 10216-5
Provedení
- metrický
Délka trubky
- 5 až 7 metrů
Číslo celního tarifu
- 73044100
All characteristics
Product description
Notes
The appropriate wall thickness needs to be calculated for tubes with bends as stipulated in DIN EN 13480-4.
*Stainless steel tubes are supplied in manufactured lengths according to EN 10216-5. In terms of production, these are usually 6 meters (+/- 1m). Order quantities are rounded to the nearest possible total length, without cutting.
Description
Our stainless‑steel tubes are tested according to DIN EN 10216‑5. The dimensional tolerances (Ø, wall thickness, ovality) are restricted in accordance with DIN EN 10305‑1 ranging from 4 to 42 mm in outer diameter (Ød1). Larger dimensions are classified according to EN ISO 1127 D3/T.
Further information
Specific load I: static (up to 120 °C)
Load case III: dynamic (up to 120 °C) stress range = P bar
Strength parameter: K 234 [N/mm²]
Safety coefficient: S 1.5
Fatigue strength: σSch/D 190 [N/mm²]
Tolerances (Ø, wall thickness, ovality) in accordance with DIN EN 10305-1
Elastic strength to DIN DIN 10216-5 Rp 1.0 to 50°C
Ordering information
Product variants
64 Results
Search
Show dimensional drawing
Identifier
Shows 10 of 64
Column selection
Ø d1 (mm)
S (mm)
Specific load I (bar)
Specific load III (bar)
Ø d2 (mm)
AD tolerance +/- (mm)
ID tolerance +/- (mm)