K- 07 45 01 27

Inline ejektor typ SLP
Pneumatic connection
4 mm 
Max. suction capacity
8 l/min
Vacuum port
4 mm 
Download PDF

Please choose a variant

Zobrazit tabulku položek
Product details for

K- 07 45 01 27

Pneumatic connection
4 mm
Max. suction capacity
8 l/min
Vacuum port
4 mm
Air consumption suction
13 l/min
Nozzle size
1
Exhaustair outlet
-
Working pressure
4.5 bar
All characteristics

Characteristics

Systém trysek
  • mosaz (typ VR) 
Použití
  • přímé uchycení na přísavku našroubováním/zasunutím do traverzy rozdělovače 
  • pro manipulaci s širokou škálou obrobků 
Přípoj
  • Thread connector 
Skříň
  • plast (typ SLP) 
Vlastnosti
  • absolutně bez opotřebení a bez údržby, bez pohyblivých částí 
  • vakuový generátor s vysokou maximální úrovní vakua (85 % vakua) 
  • absolutně úsporný, vhodný do nejužších prostor 
  • minimální spotřeba vzduchu 
  • nízké emise hluku 
Číslo celního tarifu
  • 84141089 
All characteristics

Popis výrobku

Notes
Further information on request.
Description
For vacuum generation directly at the point of use. For direct installation between the suction pad and the compressed air supply. Purely pneumatic vacuum generator that operates on the Venturi principle. Compressed air enters the ejector and flows through a nozzle. This results in a vacuum immediately behind the nozzle outlet, and air is drawn in through the vacuum inlet. This air and the driving air leave the ejector and enter the atmosphere via the exhaust air outlet.

Product variants

2 Results
Show dimensional drawing
Identifier
Pneumatic connection
Air consumption suction (l/min)
Degree of evacuation (%)
Max. suction capacity (l/min)
Details / items
4 mm 
13 l/min
85.0 %
8 l/min
Learn more
4 mm 
25 l/min
85.0 %
16 l/min
Learn more

Column selection

Pneumatic connection
Air consumption suction (l/min)
Degree of evacuation (%)
Max. suction capacity (l/min)
Nozzle size
Vacuum port
Exhaustair outlet
Working pressure (bar)