Type
4/2
Overlap
positive (closed)
suitable solenoid coil
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
Please choose a variant
Article
HK DHE 0610 X 00DC
HK DHE 0611 X 00DC
HK DHE 0613 X 00DC
HK DHE 0614 X 00DC
HK DHE 0630 2 X 00DC
HK DHE 0631 2A X 00DC
HK DHE 0631 2 X 00DC
HK DHE 0632 2 X 00DC
HK DHE 0710 X 00DC
HK DHE 0710 9 X 00DC
HK DHE 0711 X 00DC
HK DHE 0713 X 00DC
HK DHE 0714 X 00DC
HK DHE 0714 8 X 00DC
HK DHE 0714 9 X 00DC
HK DHE 0716 X 00DC
HK DHE 0717 X 00DC
HK DHE 0718 X 00DC
HK DHE 0719 1 X 00DC
HK DHE 0751 2 X 00DC
HK DHE 0711 P X 00DC
HK DHE 0713 P X 00DC
Product details for
HK DHE 0611 X 00DC
Type
4/2
Overlap
positive (closed)
suitable solenoid coil
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
Piston type
1 [PB/AT]-[A/B/P/T]
Design
spring return
All characteristics
Characteristics
Max. working pressure
- P, A, B: max. 350 bar / T: max. 210 bar
Design
- 4/2-way valve or 4/3-way valve
- 3-chamber valve
- with manual override function
- for DC coils
Connection
- ISO/Cetop 03 size 6
Flow rate
- max. 80 l/min (note characteristic curves)
Mounting
- 4 pcs. hexagon socket screw M 5 x 30 12.9
- screw set HK M5 30 for 1 basic valve. In vertical stacking applications with intermediate plates, the use of the appropriate longer screws are required.
Customs tariff number
- 84812010
All characteristics
Product description
Notes
Description
Ordering information
Delivery scope
Product variants
22 Results
Search
Show dimensional drawing
Identifier
Details / items
4/2
negative (open)
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
0 [PB/AT]-[ABPT]
4/2
positive (closed)
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
1 [PB/AT]-[A/B/P/T]
4/2
positive (closed)
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
3 [PB/AT]-[ABT/P]
4/2
negative (open)
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
4 [PA/BT]-[A/B/PT]
4/2
negative (open)
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
0/2 [PB/AT]-[PA/BT]
4/2
positive (closed)
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
1/2 [PB/AT]-[PA/BT]
4/2
positive (closed)
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
1/2 [PB/AT]-[PA/BT]
4/2
positive (closed)
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
2/2 [PB/A/T]-[PA/B/T]
4/3
negative (open)
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
0 [PB/AT]-[ABPT]-[PA/BT]
4/3
negative (open)
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
09 [PB/AT]-[ABPT]-[PAB/T]
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]
Shows 10 of 22
Column selection
Type
Overlap
suitable solenoid coil
Piston type
Design
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]